What exactly is happening?

Every problem with cause and fix

For everyone who prefers reading to clicking: every case from the troubleshooter above with the steps that fix it.

Nothing at all – no fan, no display, no light

Included power supply, no reaction

  1. Check the plug at the miner: the barrel plug must sit fully in, on USB-C devices the cable must click into place.
  2. Try another socket – power strips with a switch are a classic.
  3. Watch the power supply LED (if it has one): if it stays off, the supply is dead.
  4. If everything stays dark, it is a warranty case – send us your order number and a short video.

Contact support

Own power supply, no reaction

  1. Check the voltage: the small single-chip boards need 5 V, Bitaxe GT, 702, every NerdQaxe, NerdQX and NerdOctaxe need 12 V. A 12 V device will not start on 5 V.
  2. Check the polarity of the barrel plug: positive must be on the inside. Reversed, the device stays dark – or breaks.
  3. Check the current rating: the supply must deliver at least the amps printed on the miner.
  4. When in doubt, test again with the supply that came in the box.

Which power supply for which device?

The miner’s own Wi-Fi (Bitaxe_XXXX) does not show up

The miner is already on your home network

  1. That is normal: once a miner knows its home Wi-Fi, it no longer opens its own network. It is already on your network.
  2. Its IP address is on the display; without a display, look in your router’s device list or open http://bitaxe.local.
  3. To move it to a different Wi-Fi: enter the new network on the Network page in AxeOS and restart. If the miner can no longer find its old Wi-Fi, it opens the setup Wi-Fi by itself; on a Bitaxe you can also switch it on by holding the BOOT button for two seconds while it is running. Do not hold any button while plugging in, though, or it starts a service mode or self-test.

AxeOS explained

New device, no own Wi-Fi

  1. Hold your phone or laptop right next to the miner and refresh the Wi-Fi list. The network is called Bitaxe_XXXX, on Nerd series devices Nerdaxe_XXXX; the four characters are shown on the display.
  2. Briefly switch off mobile data on the phone: some phones jump straight back because the miner network has no internet access.
  3. Unplug the miner for a minute and plug it back in without pressing any button. The setup Wi-Fi appears after a few seconds.
  4. If it still does not show up: factory reset via the web flasher, the default install type there.

Setup guide Web flasher

Connected to my Wi-Fi, but no hash rate or no shares

The pool does not accept the connection

  1. Nine times out of ten the mistake is in the pool details (AxeOS 2.15: Pool page, Pool 1): Stratum Host gets only the name without “stratum+tcp://” and without a port, Stratum Port exactly the pool's value. AxeOS 2.15 splits a full address up by itself when you paste it.
  2. Check the User field: for solo pools your Bitcoin address (optionally .workername), for account-based pools (e.g. Braiins) accountname.worker. A typo in the address means you are mining for someone else. Replace the factory address in the fallback (Pool 2) too.
  3. Enter “x” as the password; solo pools do not evaluate it.
  4. Compare your pool values character by character with the pool configurator.
  5. After Save and Restart, enter your Bitcoin address on pool.bitaxe.de: if the miner appears there under “My miner” after one or two minutes, the settings are right.

Pool configurator My miner on pool.bitaxe.de Connected but not mining

Pool connected, still no shares

  1. Patience: depending on the pool difficulty a Gamma needs a few minutes until the first accepted share. Only after 15 minutes without a share is something wrong.
  2. Cross-check on the pool: if your miner runs on our solo pool, enter your Bitcoin address on pool.bitaxe.de. If it shows up under “My miner” with a hash rate, its shares are arriving; if it is missing, it does not reach the pool.
  3. Check the hash rate in the dashboard: if it sits at 0, the ASIC is not hashing – continue under “hash rate lower than expected”.
  4. Check the router: some routers block outgoing connections on unusual ports for “unknown devices” – rule out parental controls and device locks.
  5. Firmware current? Older AxeOS versions had stratum bugs that have long been fixed.

My miner on pool.bitaxe.de Web flasher Understanding the hash rate error

Hash rate lower than expected or hash rate error high

The miner is too hot

  1. From 70 °C at the chip the dashboard warns. Above 75 °C at the chip or 105 °C at the voltage regulator AxeOS stops mining, sets the fan to 100 % and then carries on with 100 MHz less clock and 100 mV less voltage; the dashboard shows “Device has overheated”. That is protection, not a fault.
  2. Give it air: no closed cabinet, no shelf compartment without exhaust, nothing on top of the fan.
  3. As a test, set the fan to a manual 100 % in Settings: if the temperature still stays high, the heatsink is not seated properly or thermal paste is missing.
  4. Overclocked? Back to factory values first, then improve the cooling. After an overheat, check Frequency, Core Voltage and Automatic Fan Control in Settings, because the protection changed all three.

Cooling and fans Overclocking – the limits

Cool, but still too little hash rate

  1. Compare the hourly average (“1h”) with “Expected”: below 95 % of it something is off. Then check the error: permanently below 0.1 % is very good, occasional spikes are normal. If it rises permanently, the chip gets too little voltage for its clock or the power supply is at its limit – when overclocked, raise the voltage by 10 to 20 mV or lower the clock.
  2. Check the power supply: a supply at its limit delivers less under load and the miner computes slower – without any temperature standing out.
  3. After a restart the hourly average needs an hour to become meaningful. Since AxeOS 2.11 the current value comes straight from the chip and settles after a minute.
  4. Restore factory values and watch for 24 hours before doubting the device.

Hash rate error explained Power supply guide

The miner keeps restarting

  1. This is almost always the power supply: it sags briefly under load peaks and the device reboots – with the temperature staying perfectly normal. Use a supply with headroom, no USB hub, no thin cable.
  2. Overclocked? Back to factory values. Too high a clock at too little voltage shows exactly the same way.
  3. Wi-Fi drops do not trigger a restart – but if the miner searches for minutes after every restart, it is too far from the router.
  4. If the dashboard shows “Danger: Low Voltage” or “Power Fault Detected”, it is definitely the power supply. Also keep the firmware up to date via the web flasher.

Power supply guide Web flasher

Too loud or too hot

  1. In Settings set the Target Temperature a little higher, for example 62 to 65 °C, or lower Minimum Fan Speed: the fan then spins up later. Below 65 °C chip temperature everything is fine.
  2. Location: free air on all sides, not on carpet, not in the sun. Room temperature is the cheapest lever.
  3. On the Gamma, swap the 40 mm fan for a Noctua NF-A4x20 (14.9 dB) – the biggest improvement for little money.
  4. From the 4.8 TH/s class upwards a miner stays audible; there only another room or water cooling (Hydro models) helps.

Making a Bitaxe quieter Noctua NF-A4x20

The web flasher cannot find my device

  1. Browser: only Chrome, Edge or Opera on desktop can flash over serial. Firefox and Safari cannot – there only the update via the AxeOS interface works.
  2. Cable: it has to be a data cable, directly on the computer, no USB hub. Charge-only cables never show up as a port.
  3. Driver: if nothing appears in the port dialog, the serial bridge driver is usually missing on Windows – install CP210x or CH340 and restart the browser.
  4. Port in use? No other program (Arduino IDE, terminal) may hold the port open.
  5. Still stuck: open recovery mode in the flasher. It walks you through starting with the BOOT button held, after that the miner is found.

Go to the web flasher AxeOS update without the flasher